Council, estate & planning rules

Published 23 Sept 20268 min read

Setback rules in Victoria: front, side and rear setbacks explained

A suburban house sits behind a driveway and front lawn, with neighboring homes and a street tree.

For a new house in Victoria, the minimum front setback is generally 4 m from a standard street or 6 m from a major arterial road when there are no houses on the neighbouring lots. Side and rear walls up to 3.6 m high generally need to be at least 1 m from the boundary. The rules that apply depend on the block and the type of approval required. Most standard house lots are assessed under Victoria's building rules, while some smaller lots and multi-dwelling developments are assessed under separate planning rules. Small lots in some new estates can also have different setbacks under the Small Lot Housing Code or the estate's registered building envelope.


Published 23 Sept 2026

Front setback, standard street, no house on the adjoining lots
4 m
Building Regulations 2018 Table 74 and clause 54 Standard A2-1; 6 m on a declared road or a Transport Zone 2 street
Side and rear setback, wall up to 3.6 m high
1 m
Table 79, Standard A2-3 and the Small Lot Housing Code Table 5; plus 0.3 m for every metre of height over 3.6 m
Wall on a boundary, maximum height
3.6 m
Regulation 80 and Standard A2-4: an average of 3.2 m, for 10 m plus 25% of the remaining boundary length
Planning permit trigger for one house, General Residential Zone
Less than 300 m²
Clause 32.08-5; a Small Lot Housing Code lot that complies with the code needs no planning permit
What is a setback?What is a setback?The national explainer covers how a setback is measured, what may encroach into it, and how the New South Wales, Victorian and Queensland codes compare on a typical new lot.Building envelope explainedBuilding envelope explainedThe envelope is the area left once the setbacks come off a block. On a 15 m by 30 m corner lot, the Building Regulations 2018 default setbacks leave a 12 m by 25 m envelope of 300 m².What is site coverage?What is site coverage?Setbacks fix where a house can stand and site coverage fixes how much of the lot its roof can cover. The 60 per cent site coverage limit under the Building Regulations 2018 and the planning scheme's garden-area bands sit alongside the setbacks on the same block.

Section 01 · The instruments

Which setback rules apply to a new house in Victoria?

The setback rules for a new house in Victoria depend mainly on the size of the lot, whether a planning permit is required and whether separate small-lot or estate rules apply.

For many standard house lots, the setbacks are checked as part of the building permit. These rules cover front, side and rear setbacks, as well as walls built along a boundary.

Where a planning permit is required for one house, Victoria's planning rules apply instead. In the General Residential Zone, a permit is generally needed for a house on a lot smaller than 300 m². On a lot of 300 m² or more, the building rules generally apply unless something else triggers a planning permit.

Separate planning rules apply to developments with two or more dwellings on one lot and certain residential buildings of up to three storeys1.

Different rules can also apply in some newer estates. Lots smaller than 300 m² may be covered by the Small Lot Housing Code. If the house meets the code and the required conditions, a separate planning permit may not be needed2.

An estate can also have a registered building envelope that sets where a house can sit on the block. Where the envelope sets a different requirement for the same setback, it can replace the standard building rule for that lot.

The Building Regulations row is the default path for a house on a lot of 300 m² or more with no other permit trigger. Zone schedules in the planning schemes listed in Schedule 6 of the regulations can set their own street, side and rear setbacks and boundary-wall lengths, which then apply in place of the regulation's table.
Setback instruments for a new house by approval path, Victoria, 2026
InstrumentApproval pathApplies toSetback provisions
Building Regulations 2018, Part 5Building permitA single Class 1 building and its Class 10a buildings where no planning permit is requiredreg 73 maximum street setback; reg 74 minimum street setbacks; reg 79 side and rear setbacks; reg 80 walls and carports on boundaries
VPP clause 54 (ResCode)Planning permitOne dwelling or a small second dwelling where a permit is required, such as one dwelling on a lot of less than 300 m² in the General Residential Zone54.02-1 street setback; 54.02-3 side and rear setbacks; 54.02-4 walls on boundaries; 54.02-8 small second dwellings
VPP clause 55 (ResCode)Planning permitTwo or more dwellings on a lot and residential buildings of three storeys or less55.02-1 street setback; 55.02-3 side and rear setbacks; 55.02-4 walls on boundaries
Small Lot Housing Code, November 2024Building permit, no planning permit where the code is metLots of less than 300 m² nominated Type A, B or C on the plan of subdivision in growth-area precinctsStandards 2, 7 and 8 (Type A and B); Standards 27, 28 and 29 (Type C)
Estate approved building envelopeBuilding permit, through reg 71Lots whose section 173 agreement or plan of subdivision records an approved building envelopeThe building envelope plan, profile diagrams and written notes

Source · Building Regulations 2018 (Vic), regs 5(1), 71, 72, 73, 74, 79 and 80; Victoria Planning Provisions, clauses 32.08-5, 54 and 55; Small Lot Housing Code, November 2024, Chapter 1.

Section 02 · The street

How far from the street must a house be set back in Victoria?

The minimum front setback for a house on a lot with no dwelling on either adjoining lot is 4 m from a standard street. This increases to 6 m on a declared road, such as a freeway or arterial road3.

Where houses stand on both neighbouring lots, the building rules generally use the average of their front setbacks, capped at 9 m. Where only one neighbouring lot has a house, its front setback is used, also capped at 9 m3.

The regulations also cap the front setback. A house cannot be set back more than one-third of the lot's depth unless the lot is at least 0.40469 ha (about one acre)3.

On a corner lot, the setback from the side street is generally 2 m. A smaller setback can apply where the neighbouring house facing that street sits closer to the road.

Different front-setback calculations apply where a planning permit is required. With no neighbouring houses, the minimum is still 4 m, increasing to 6 m on a main road in Transport Zone 2. Where houses stand on the neighbouring lots, the setback is generally the smaller of the two neighbouring front setbacks, capped at 6 m.

Corner lots assessed under the planning rules generally require front walls facing the side street to be at least 3 m back and side walls at least 2 m back. A smaller setback can apply where the neighbouring house facing that street sits closer to the road.

This means the required setback can differ depending on the approval path. For example, a 450 m² lot between houses set back 7 m and 9 m would generally require an 8 m front setback under the building rules. A 280 m² lot in the General Residential Zone between the same houses would generally be assessed against a 6 m setback under the planning rules. A local planning rule can also set a different setback for a particular area.

Some building features can extend into the front setback. Porches, verandahs and pergolas under 3.6 m high can generally extend up to 2.5 m into it. So can eaves, gutters and shade sails, and decks, steps or landings under 800 mm high3. A small second dwelling must sit behind the front wall of the existing house.

Not used: the Small Lot Housing Code sets its street setbacks by lot type and does not average neighbouring buildings, and Table 8 sets one front figure for a Type C lot on any street. The regulations also cap the front setback at one-third of the lot depth on lots of less than 0.40469 ha. A garage or carport door facing the street on a Type A or B lot sits at least 5.0 m from the front street alignment or 2.0 m from a secondary street.
Minimum street setbacks for a house by instrument and neighbouring development, Victoria, 2026
InstrumentNo dwelling on the adjoining lotsDwellings on the adjoining lotsDeclared or major roadSide street on a corner lot
Building Regulations 2018, Table 744 mAverage of the neighbours' front walls, or 9 m, whichever is less6 m, declared road2 m, or the neighbour's front wall where less
VPP clause 54, Table A2-1, and clause 55, Table B2-14 mLesser of the neighbours' front walls, or 6 m, whichever is less6 m, Transport Zone 2 street3 m for front walls, 2 m for side walls, or the neighbour's front wall where less
Small Lot Housing Code, Type A, Table 13.0 m; 1.5 m opposite an open space reserveNot used4.0 m, declared road1.5 m
Small Lot Housing Code, Type B, Table 11.5 mNot used4.0 m, declared road1.0 m
Small Lot Housing Code, Type C, Table 82.5 mNot used2.5 m1.5 m, plus 0.5 m for every metre of height over 6.9 m

Source · Building Regulations 2018 (Vic), regs 73 and 74; Victoria Planning Provisions, clauses 54.02-1 and 55.02-1; Small Lot Housing Code, November 2024, Tables 1 and 8 and Standard 2.3.

Default setbacks on a corner lot, Building Regulations 2018

Illustrative plan view of a 15 m by 30 m corner lot, 450 m², with the front street at the bottom and the side street on the right: the Building Regulations 2018 default setbacks of 4 m to the front street, 2 m to the side street, 1 m to the side boundary and 1 m to the rear boundary leave a building envelope 12 m by 25 m, or 300 m²; a thick line along the left boundary marks the 15 m over which a wall may sit on the boundary under regulation 80, 10 m plus 25 per cent of the remaining 20 m, at a maximum height of 3.6 m
Illustrative plan, not a real parcel: a 15 m × 30 m corner lot of 450 m² with no dwelling on the adjoining lots and a standard street. Table 74 sets 4 m to the front street and 2 m to the side street, and Table 79 sets 1 m to the side and rear boundaries for walls up to 3.6 m high, leaving an envelope of 12 m × 25 m, or 300 m². Regulation 80 allows a wall on the left boundary for 15 m, from 10 m plus 25% of the remaining 20 m, at a maximum height of 3.6 m.

How the side-street setback and the second frontage work on a corner block is covered in the corner lot rules article.

Section 03 · Side and rear

How close to a side or rear boundary can a house be in Victoria?

The minimum side or rear setback for a wall up to 3.6 m high is generally 1 m in Victoria. The required distance increases as the wall gets higher3.

The standard setbacks are:

  • 1 m for a wall of 3.6 m or less.
  • 1 m plus 0.3 m for every metre of height over 3.6 m, for a wall of more than 3.6 m and up to 6.9 m.
  • 2 m plus 1 m for every metre of height over 6.9 m, for a wall of more than 6.9 m.

For example, a 5 m wall needs a setback of 1.42 m, while a 6.9 m wall needs 1.99 m. An 8 m wall needs a setback of 3.1 m. The setback is worked out from the wall's height at each point along it.

The same basic height-based calculation applies under the building rules, the planning rules for a single house and the Small Lot Housing Code for Type A and B lots7.

Different rules can apply to developments with two or more dwellings. One option under those rules allows a building up to 11 m high to sit at least 3 m from most boundaries, or at least 6 m from a boundary on the southern side of the property1.

Some building features can extend into the required side or rear setback. Under the building rules, eaves, fascias and gutters can generally extend up to 600 mm into it, while features such as porches, verandahs, chimneys, pipes, tanks and heating or cooling equipment can generally extend up to 500 mm. Other rules apply to some features under the planning system3.

If a house does not meet the standard building setback, the council must consent before a building permit can be issued. Where a planning permit is required, the council assesses a design that falls outside the standard planning setback as part of the permit process3.

Worked values on the formula, illustrative: 1.42 m for a 5 m wall, 1.99 m for a 6.9 m wall and 3.1 m for an 8 m wall. Clause 55's Standard B2-3 is met by either B2-3.1 or B2-3.2. A Type C lot's side setback to another Small Lot Housing Code lot is 1.0 m, plus 0.5 m for every metre over 6.9 m, and its rear setback from a street, laneway or open space reserve is 1.0 m. A wall on or within 200 mm of the boundary is governed by the boundary-wall rules instead.
Minimum side and rear setbacks by wall height and instrument, Victoria, 2026
Wall height at any pointBuilding Regulations Table 79, clause 54 Standard A2-3, clause 55 Standard B2-3.1, Small Lot Housing Code Table 5Clause 55 Standard B2-3.2, boundary not to the southClause 55 Standard B2-3.2, boundary to the southSmall Lot Housing Code Type C, Table 9, rear boundary not a street
3.6 m or less1 m3 m6 m4.0 m
More than 3.6 m, up to 6.9 m1 m plus 0.3 m for every metre over 3.6 m3 m6 m4.0 m
More than 6.9 m2 m plus 1 m for every metre over 6.9 m3 m up to 11 m; 4.5 m above 11 m6 m up to 11 m; 9 m above 11 m4.0 m plus 0.5 m for every metre over 6.9 m

Source · Building Regulations 2018 (Vic), reg 79; Victoria Planning Provisions, clauses 54.02-3 and 55.02-3; Small Lot Housing Code, November 2024, Tables 5 and 9.

Minimum side and rear setback by wall height, Victoria

Illustrative section view of the minimum side or rear setback against wall height under Table 79 of the Building Regulations 2018 and Standard A2-3 of clause 54: 1 m for walls up to 3.6 m, rising by 0.3 m for every metre of height to 1.99 m at 6.9 m, then 2 m plus 1 m for every further metre, so 3.1 m at 8 m
Section through a side boundary. The stepped line is the closest a wall may stand to the boundary at each height under Table 79 of the Building Regulations 2018, which Standard A2-3 of clause 54 and Table 5 of the Small Lot Housing Code repeat: 1 m up to 3.6 m, then 0.3 m more for every metre of height to 6.9 m, then 2 m plus 1 m for every further metre.

Section 04 · Boundary walls

How much of a boundary can a wall cover in Victoria?

A wall on or within 200 mm of a side or rear boundary may run for 10 m plus 25 per cent of the boundary length beyond the first 10 m. If there is already a longer wall on the neighbouring property, the new wall may be able to match that length where the two walls meet3.

On a 30 m boundary, this gives a maximum length of 15 m.

The wall's average height must not be more than 3.2 m, and no part can generally be higher than 3.6 m3. Where the new wall meets an existing boundary wall, it may be able to match the height of that wall.

The same general length and height limits apply where the house is assessed under Victoria's planning rules. In some cases, the length limit does not apply where the wall is effectively less than 2 m high on the neighbouring side because of the slope of the land, a retaining wall or a fence7.

Different rules apply on some lots covered by the Small Lot Housing Code. On Type A and B lots, a wall on or very close to a side or rear boundary can run the full length of that boundary, provided the other requirements are met. The usual maximum height is 3.6 m, increasing to 6.9 m along a laneway boundary2.

For Type C lots, a boundary wall can also run without the standard length limit, with a maximum height of 6.9 m on a side or rear boundary that is not a side street.

The Small Lot Housing Code heights may be exceeded only where the wall abuts an existing or simultaneously approved wall within the stated height difference. The Alamora row is an estate rule that applies through the lot's registered building envelope, not a statutory figure.
Walls on side and rear boundaries by instrument, Victoria, 2026
InstrumentWall coveredMaximum lengthMaximum height
Building Regulations 2018, reg 80Wall on or within 200 mm of a side or rear boundary; carport within 1 m open to the boundary10 m plus 25% of the remaining boundary length, or the length of an abutting existing wallAverage 3.2 m, lengths less than 2 m high excluded; no part over 3.6 m; or the height of an abutting wall
VPP clause 54, Standard A2-4, and clause 55, Standard B2-4Wall on or within 200 mm; carport within 1 m10 m plus 25% of the remaining boundary length, or the length of existing or simultaneously built walls; no limit where the effective height is less than 2 mAverage 3.2 m; no part over 3.6 m unless abutting a higher wall
Small Lot Housing Code, Type A and B, Standard 8Wall on or within 200 mm of a side or rear boundary, not a laneway; carport within 1.0 mNo maximum3.6 m; 6.9 m on a laneway boundary
Small Lot Housing Code, Type C, Standard 29Wall on or within 200 mm of a side or rear boundary including a lane, not a side streetNo maximum6.9 m
Alamora Design Guidelines, section 3.5(vi)Walls within 1.0 m of a boundary, inside the lot's Building to Boundary Zone60% of the boundary length, one side boundary only; terrace lots excepted3.6 m

Source · Building Regulations 2018 (Vic), reg 80; Victoria Planning Provisions, clauses 54.02-4 and 55.02-4; Small Lot Housing Code, November 2024, Standards 8 and 29; Alamora Design Guidelines, version 2.11, section 3.5(vi).

What a wall on the boundary means for a design, and how builders treat the zero-lot side, is covered in the zero-lot boundary walls article.

Section 05 · Small lots and estates

How do small-lot and estate rules change the setbacks in Victoria?

Small lots and some new estates can have different setbacks from Victoria's standard building rules. Under the Small Lot Housing Code, the setback depends on whether the lot is classified as Type A, B or C.

On a Type A lot, the front setback is generally 3.0 m on a standard street, 4.0 m facing a declared road and 1.5 m where an open space reserve sits across the street. On a Type B lot it is 1.5 m, or 4.0 m facing a declared road2.

The secondary street setback on a corner is 1.5 m for Type A and 1.0 m for Type B2. A garage or carport door facing the front street must generally be at least 5.0 m from the street boundary, or 2.0 m from a secondary street.

Type C lots have different rules. The front setback is 2.5 m and the rear setback is 4.0 m where the rear boundary is not a street2.

The lot type is recorded when the subdivision is approved. A house must meet the rules for that particular lot type to use the Small Lot Housing Code. If it does not, a planning permit is required instead2.

Estate-specific rules can add another layer. At Alamora in Tarneit, for example, the general front setback is 4 m, as shown on each lot's building envelope. The guidelines also require a 1 m setback from one side boundary and a 3 m rear setback for a wall up to 3.6 m high. In some stages, the rear setback increases to 5.5 m for taller walls8.

Walls built within 1 m of a side boundary at Alamora are generally restricted to one side of the lot. They can cover up to 60 per cent of that boundary and be no higher than 3.6 m. Where a wall is less than 1 m from the boundary, it must generally sit within 200 mm of it.

These estate rules are recorded against the affected lots and can replace the standard Victorian setback rules for the matters they cover. At Alamora Stage 3, the registered rules apply to lots 301 to 350 and require buildings to follow the approved building envelopes. Those restrictions are due to end on 1 January 20319.

Each layer applies only where it is triggered: the Small Lot Housing Code where the plan of subdivision nominates the lot type, and the Alamora figures where the lot's memorandum of common provisions records the building envelope. The per-lot envelope plan can vary the estate's general figures.
Setback layers on a growth-area lot at Tarneit, Victoria, 2026
LayerFrontSideRearWall on the boundary
State default: Building Regulations 2018, standard street, no adjoining dwellings4 m1 m for a wall up to 3.6 m1 m for a wall up to 3.6 m10 m plus 25% of the remaining length; 3.6 m maximum, 3.2 m average
Small Lot Housing Code, Type A lot of less than 300 m²3.0 m; garage door 5.0 m1.0 m for a wall up to 3.6 m1.0 m for a wall up to 3.6 mNo maximum length; 3.6 m
Alamora Design Guidelines and Stage 3 memorandumGenerally 4 m, per the building envelope; garage behind the front facade1 m from one side boundary3 m for a wall up to 3.6 m; 5.5 m for a taller rear wall in Stages 1 to 6 and 9 to 11One side only, within the Building to Boundary Zone; 60% of the boundary length; 3.6 m

Source · Building Regulations 2018 (Vic), regs 74, 79 and 80; Small Lot Housing Code, November 2024, Tables 1 and 5 and Standards 2.3 and 8; Alamora Design Guidelines, version 2.11, section 3.5; Alamora Stage 3 Memorandum of Common Provisions.

How an estate's design approval sits alongside the statutory approval is covered in the design guidelines article.

Section 06 · The block

What determines the setbacks for a block in Victoria?

The setbacks for a block in Victoria can depend on four main factors:

  • The lot and estate rules. Some small lots are covered by the Small Lot Housing Code, while some estates have a registered building envelope that sets where the house can sit.
  • The local planning rules. These determine whether a planning permit is required and can set different front, side or rear setbacks for particular areas.
  • The type of road. Some freeways and arterial roads have a 6 m front setback instead of 4 m where there are no houses on the adjoining lots.
  • Neighbouring houses. Where houses already stand on adjoining lots, their front setbacks can affect the required setback. Under the building rules, the average of the neighbouring setbacks is generally used, capped at 9 m. Under the planning rules, the smaller neighbouring setback is generally used, capped at 6 m.

The exact setback can therefore vary from one block to another. Small-lot classifications, estate building envelopes and local planning rules can change the standard Victorian figures.

How BuildStreet calculates setbacks for a block

BuildStreet reads a lot's dimensions from the official land-parcel map and applies the Victorian setback rules available for that block. It then shows the remaining building area and which catalogue house designs fit within it. Where an estate-specific rule or building envelope is not available, the result shows the standard state rule and flags the estate requirement as still to be checked.

Section 07

Frequently asked questions

What is the minimum side setback in Victoria?

The minimum side setback in Victoria is 1 m for a wall up to 3.6 m high. For taller walls, the setback increases with the height of the wall. Between 3.6 m and 6.9 m, it increases by 0.3 m for every additional metre of height. Above 6.9 m, the setback is 2 m plus 1 m for every additional metre.

What is the front setback for a new house in Victoria?

The minimum front setback for a new house in Victoria is generally 4 m from a standard street and 6 m from a declared road, such as a freeway or major arterial road, where there are no houses on the adjoining lots. Where neighbouring houses are already present, their front setbacks can affect the required distance. The calculation also differs depending on whether the house is assessed under the building or planning rules.

Does ResCode apply to a single house in Victoria?

Yes, but only where a planning permit is required. In the General Residential Zone, this generally includes a single house on a lot smaller than 300 m². A house on a larger lot with no other planning permit requirement is generally assessed under Victoria's building rules instead.

What is the difference between clause 54 and clause 55?

Clause 54 generally applies to one house or a small second dwelling where a planning permit is required. Clause 55 applies to developments with two or more dwellings on a lot and certain residential buildings of up to three storeys. Both include rules for front, side and rear setbacks and walls along boundaries.

Can a house be built on the boundary in Victoria?

Yes. A wall can generally sit on or within 200 mm of a side or rear boundary for up to 10 m plus 25 per cent of the remaining boundary length. Its average height is generally limited to 3.2 m, with no part higher than 3.6 m unless it meets an existing higher boundary wall. Different rules can apply on some small lots and estates.

Do estate design guidelines override the Victorian setback rules?

They can, where a registered building envelope or other approved estate rule sets a different requirement for the same setback. At Alamora in Tarneit, for example, some lots have a 3 m rear setback instead of the standard 1 m setback for a wall up to 3.6 m high.

References

  1. Victoria Planning Provisions, clause 55 (Two or more dwellings on a lot and residential buildings of three storeys or less), Amendment VC267 · planning-schemes.app.planning.vic.gov.au ↑ b c
  2. Small Lot Housing Code (Victorian Planning Authority, November 2024) · vpa-web.s3.amazonaws.com ↑ b c d e f g h i j k
  3. Building Regulations 2018 (Vic), authorised version 031, incorporating amendments as at 1 September 2026 · content.legislation.vic.gov.au ↑ b c d e f g h i j k l m n o
  4. Victoria Planning Provisions, clause 32.08 (General Residential Zone), Amendment VC267 · planning-schemes.app.planning.vic.gov.au ↑
  5. Amendment VC282, amendment record (Department of Transport and Planning, Victoria) · planning-schemes.app.planning.vic.gov.au ↑
  6. Amendment VC267, amendment record (Department of Transport and Planning, Victoria) · planning-schemes.app.planning.vic.gov.au ↑
  7. Victoria Planning Provisions, clause 54 (One dwelling on a lot or a small second dwelling on a lot), Amendment VC282 · planning-schemes.app.planning.vic.gov.au ↑ b c d e f
  8. Alamora Design Guidelines (Villawood, Tarneit VIC, October 2024) · villawoodproperties.com.au ↑ b c
  9. Alamora Stage 3 Memorandum of Common Provisions (Villawood, Tarneit VIC) · villawoodproperties.com.au ↑