Blocks & boundaries

Published 23 Sept 20269 min read

Queensland house setback rules: front, side and rear distances explained

Detached houses sit back from a suburban street, with driveways, front lawns and planted gardens.

Queensland's house setback rules set the minimum distances a home generally needs to be from the road and the side and rear boundaries. The default distances depend mainly on the size of the lot. Under the Queensland Development Code (QDC), MP1.1 applies to lots under 450 m² and MP1.2 applies to lots of 450 m² or more. Smaller lots generally have a front setback of 3 m or 4 m depending on the street type, while larger lots generally have a 6 m front setback. Side and rear clearances generally start at 1.5 m for walls up to 4.5 m high. These are the state default rules. Different requirements can apply where a council planning scheme, priority development area or estate guideline sets its own rules. From 1 September 2026, councils can also adopt the Queensland Housing Code. Until that happens, the existing QDC rules or local requirements continue to apply.


Published 23 Sept 2026

MP1.2 road setback, lot of 450 m² or more
6 m
Acceptable solution A1(a)(i) for a dwelling, garage or carport, or a distance between the adjoining houses where at least one sits 3 m to 6 m from the road
MP1.1 road setback, access street, lot under 450 m²
3 m
Table A1: 3.0 m on an access place or access street, 4.0 m on a collector street; 1.0 m and 2.0 m to a corner street
Side and rear clearance, wall 4.5 m or less
1.5 m
A2(a) in both parts; 2 m for a part between 4.5 m and 7.5 m high; Table A2 reduces both on a frontage of 15 m or less
Queensland Housing Code transition ends, 1 September
2029
Three-year transition from 1 September 2026 in which the code applies only where a council's planning scheme is amended to adopt it
What is a setback?What is a setback?The setback article explains front, side and rear setbacks in plain words, how they are measured and how the building envelope is drawn from them, across every state.Zero-lot boundary wallsZero-lot boundary wallsThe QDC has no zero-lot option for a house wall, so a built-to-boundary design in Queensland rides on an estate's own plan. The boundary-wall article covers where that siting is allowed.

Section 01 · The rule

What are the QDC setback rules for a house in Queensland?

Queensland's default setback rules depend mainly on the size of the lot. The Queensland Development Code (QDC) uses MP1.1 for a single detached house on a lot under 450 m² and MP1.2 for a lot of 450 m² or more.1 Both set default front, side and rear setbacks for the house, as well as garages, sheds and carports on the same lot.

Setbacks are measured from the outermost part of the building to the boundary. For a roof, this includes the outside face of the fascia rather than just the wall.1

The QDC figures are the standard setbacks that can generally be approved without further assessment. A design that does not meet them may still be considered, but it needs to be assessed against broader requirements such as streetscape, daylight, ventilation and neighbour privacy.2

The QDC does not always provide the final setback for a block. A council planning scheme can set different requirements, and different rules can also apply inside a priority development area.3 Estate design guidelines may add another layer of requirements. Where one of these replaces or adds to the state rules, the setback for that block can differ from the QDC default.

Every value is an acceptable solution: the siting a certifier can approve without assessment against the performance criteria. Both parts exclude development in an urban development area, the term the 2010 editions use for what the Economic Development Act 2012 now calls a priority development area.
QDC acceptable solutions for a detached house by lot size, Queensland, 11 March 2010 editions
ElementMP1.1, lot under 450 m²MP1.2, lot of 450 m² or moreClause
Road setback, house, garage or carport3.0 m on an access place or access street; 4.0 m on a collector street6 mA1(a), Table A1
Road setback, neighbour-averaging ruleWhere houses on both adjoining lots exist and at least one sits 3 m to 6 m from the road: a distance between the two, or their average where they differ by more than 2 mSame ruleA1(a)(ii)
Corner lot, secondary street1.0 m on an access street; 2.0 m on a collector street, where the average lot depth is 24 m or less6 m, or the Table A1 figure on the nominated frontage where the average depth is 24 m or lessA1(c) in MP1.1; A1(b) in MP1.2
Side and rear clearance, part up to 4.5 m high1.5 m1.5 mA2(a)(i)
Side and rear clearance, part 4.5 m to 7.5 m2 m2 mA2(a)(ii)
Side and rear clearance, part above 7.5 m2 m plus 0.5 m for every 3 m or part of 3 m above 7.5 mSame ruleA2(a)(iii)
Narrow-lot reduction, frontage 15 m or lessTable A2, by frontage bandTable A2, by frontage bandA2(b)
Site cover, all roofed buildings50% of the lot area50% of the lot areaA3
Building height8.5 m on a slope up to 15%; 10 m on a slope of 15% or moreSame ruleA4
Wall maintenance clearance750 mm from a side or rear boundary, or a maintenance-free wallSame ruleA6

Source · QDC MP 1.1 and MP 1.2, publication date 11 March 2010, Element 1

Section 02 · Small lots

What are the setback rules for lots under 450 m²?

For a lot under 450 m², the Queensland Development Code rules generally require a front setback of 3 m on an access place or access street and 4 m on a collector street.1

On a corner lot, the setback from the second street is generally 1 m on an access street and 2 m on a collector street. Different front setbacks can also apply where houses already stand on both neighbouring lots and at least one is between 3 m and 6 m from the road. In that case, the new house can generally follow a setback based on the neighbouring houses.

A garage or carport generally follows the same front setback as the house. On a rectangular lot, garage doors facing the street can be no wider than 6 m or half the lot frontage, whichever is less.

The general side and rear clearance is 1.5 m for parts of the building up to 4.5 m high and 2 m for parts between 4.5 m and 7.5 m high.1

Smaller clearances can apply on rectangular or near-rectangular lots with a frontage of 15 m or less. The permitted clearance becomes smaller as the frontage narrows.

The table applies to a rectangular or near-rectangular lot only, and a part higher than 7.5 m takes 2 m plus 0.5 m for every 3 m or part of 3 m above 7.5 m. The same table appears in both parts, so it also serves a lot of 450 m² or more with a frontage of 15 m or less.
QDC Table A2 side and rear boundary clearances by road frontage, rectangular lots of 15 m or less, Queensland
Road frontagePart up to 4.5 m highPart above 4.5 m and up to 7.5 m
14.501 m to 15.000 m1.425 m1.900 m
14.001 m to 14.500 m1.350 m1.800 m
13.501 m to 14.000 m1.275 m1.700 m
13.001 m to 13.500 m1.200 m1.600 m
12.501 m to 13.000 m1.125 m1.500 m
12.001 m to 12.500 m1.050 m1.400 m
11.501 m to 12.000 m0.975 m1.300 m
11.001 m to 11.500 m0.900 m1.200 m
10.501 m to 11.000 m0.825 m1.100 m
10.500 m or less0.750 m1.000 m

Source · QDC MP 1.1 and MP 1.2 (11 March 2010), A2(b) and Table A2

Worked example · 12.5 m frontage lot under MP1.1

In an illustrative calculation for a rectangular 12.5 m by 32 m lot on an access street, the side clearances are 1.05 m for a single-storey part up to 4.5 m high. This leaves 10.4 m between the two side setbacks. With a 3 m front setback and a 1.05 m rear clearance, the available depth is 27.95 m. A two-storey part between 4.5 m and 7.5 m high needs 1.4 m side clearances, leaving 9.7 m between the side setbacks. The maximum site cover is 200 m², or 50% of the 400 m² lot. A garage door facing the street can be up to 6 m wide.

The 9 m truncation and the secondary-street setback are the corner-lot rules that the corner blocks article compares across the states.

Section 03 · Larger lots

What are the setbacks for a lot of 450 m² or more?

For a lot of 450 m² or more, the Queensland Development Code rules generally require a 6 m front setback for a house, garage or carport.4

Where houses already stand on both neighbouring lots and at least one is between 3 m and 6 m from the road, a different setback based on the neighbouring houses can apply.

On a corner lot, the second street generally also has a 6 m setback. However, different rules can apply where the average lot depth is 24 m or less. A structure more than 2 m high also cannot be placed within the 9 m by 9 m area at the street corner.

An open carport can sometimes be closer to the road where there is no suitable compliant location elsewhere on the lot. To qualify, the walls and posts inside the setback can make up no more than 15% of the carport's perimeter.

The side and rear clearances are the same as for smaller lots: 1.5 m for parts of the building up to 4.5 m high and 2 m for parts between 4.5 m and 7.5 m high.4

Above 7.5 m, the clearance starts at 2 m and increases by 0.5 m for every additional 3 m, or part of 3 m. Smaller clearances can apply on rectangular or near-rectangular lots with a frontage of 15 m or less. Site cover is limited to 50% of the lot. The maximum building height is 8.5 m on slopes up to 15% and 10 m on steeper slopes.4

A wall closer than 750 mm to a side or rear boundary must be designed so it does not require access from the neighbouring property for maintenance. Windows and balconies close to a side or rear boundary also need privacy measures such as screening, a high window sill or obscure glazing.

Section 04 · Council overrides

When can a Queensland council set different setback rules?

A Queensland council can set different setback or siting rules in its planning scheme instead of using the QDC defaults. Where the council has its own rule for a particular matter, that rule takes priority. The QDC continues to apply to matters the council has not changed.3

The Queensland Government said in August 2026 that about three-quarters of councils had different housing requirements, which is one reason setback rules can vary between council areas.6

Logan City Council is one example. Its planning scheme uses the QDC as the starting point but changes some requirements for particular areas. In Logan's low-medium density residential zone, the front setback is 4 m.7 In the small lot precinct of the low density residential zone, site cover can be up to 60%. Some acreage and rural residential areas require 3 m side and rear setbacks and a 10 m front setback. For an ordinary lot in Logan's low density residential zone, the planning scheme does not set different figures for these matters, so the QDC defaults continue to apply.

Brisbane City Council also has its own rules for some lots. Lots under 450 m² generally use Brisbane's small lot rules instead of the QDC, while standard lots of 450 m² or more generally use the QDC rules for larger lots. A rear lot under 600 m² is also treated as a small lot in Brisbane. Brisbane's small lot rules set their own setback distances, so check them with Brisbane City Council for the figures that apply to a particular block.

The Logan outcomes prevail over the QDC reference in AO1 to the extent of any inconsistency; matters the code does not list keep the QDC value.
Logan City Council's alternative provisions compared with the QDC acceptable solutions, Logan Planning Scheme 2015 version 9.2
MatterLogan dwelling house codeQDC default
Road clearance, low-medium density residential zone4 m, AO4(b)3 m or 4 m by street type under 450 m²; 6 m at 450 m² or more
Carport at the front boundaryPermitted to 6 m by 6 m and 3.5 m high, unenclosed, AO4(a)Road setback as for the house; open carport concession in MP1.2 only
Road clearance, acreage, rural residential and emerging community areas10 m, AO4(c)3 m to 6 m
Side and rear clearance, rural residential, emerging community and acreage areas3 m, AO5(a)1.5 m to 2 m by wall height
Site cover, low density residential small lot precinct60%, AO3(a)50%
Corner lot, nominated road frontageThe narrower frontage, AO1 noteNominated by the local government
Ordinary lot, low density residential zoneNo value listed; AO1 applies the QDC partQDC figures stand

Source · Logan Planning Scheme 2015 v9.2 (effective 1 July 2025), Part 1 Table 1.6.1 and Part 9.3.2 Table 9.3.2.3.1; QDC MP 1.1 and MP 1.2 (11 March 2010)

Section 05 · Priority development areas

How do priority development areas affect setback rules?

A priority development area (PDA) can have its own setback and building rules instead of the council's usual planning rules.

These areas are generally planned for major housing or development projects. Each PDA has its own development scheme, which sets the rules that apply within its boundary. Economic Development Queensland assesses applications in most PDAs, although councils manage some areas.

Yarrabilba in Logan is one example. Its development scheme uses the QDC setback rules for many detached houses. Lots from 400 to 450 m² generally use the rules for smaller lots, while lots above 450 m² generally use the rules for larger lots.

The scheme also sets some of its own requirements. The maximum building height is 9 m, compared with the QDC's 8.5 m default. It also includes requirements for outdoor living space, covered parking, driveway width and front fencing.

For some houses on lots of at least 400 m² with a frontage of at least 12.5 m, no separate planning application is required where the development meets the scheme's requirements and the lot is outside specified constraint areas.

Yarrabilba covers 2,222 hectares and is planned for about 20,000 homes.8 Other major residential PDAs in south-east Queensland have their own development schemes and housing rules.

The seven areas are the residential growth areas the fact sheet lists in south-east Queensland with a dwelling figure; inner-city and infrastructure areas are omitted. Dwelling figures are each area's planned yield at full development as published.
Residential priority development areas in south-east Queensland, declaration date, area and planned dwellings
Priority development areaCouncil areaDeclaredAreaPlanned dwellings
Greater FlagstoneLoganOctober 20107,188 ha50,000
Ripley ValleyIpswichOctober 20104,680 ha50,000
WarabaMoreton BayAugust 20242,900 haAbout 30,000
Caloundra SouthSunshine CoastOctober 20102,310 ha20,000
YarrabilbaLoganOctober 20102,222 haAbout 20,000
Southern ThornlandsRedlandApril 2025890 haAbout 8,000
North HarbourMoreton BayJuly 2025421 haAbout 3,700

Source · Economic Development Queensland, Priority Development Areas fact sheet (December 2025)

Section 06 · Housing Code

How does the Queensland Housing Code change setback rules?

The Queensland Housing Code is replacing the older QDC rules for detached houses, but it does not yet apply automatically in every council area.

The new code was released in August 2026 and covers setbacks, building height, privacy, parking, site cover and private open space. A transition period runs from 1 September 2026 to 1 September 2029.10 During this period, the Housing Code applies in a council area only after the council updates its planning scheme to adopt it.

Where a council has not yet adopted the new code, the existing QDC rules or the council's own local requirements continue to apply. The Housing Code is intended to create a more consistent set of housing rules across Queensland, replacing many of the different local requirements that councils have introduced over time.

To find out which setback distances apply to a block during the transition, check whether the local council has adopted the Housing Code.

Section 07 · Estates

How do estate design guidelines affect setback rules?

Estate design guidelines can add extra setback and building requirements on top of the state and council rules. In many south-east Queensland estates, the exact setbacks for a block are shown on a separate plan issued for that lot rather than in the public design guidelines.

For example, Yarrabilba and Springfield Rise both refer to lot-specific setback plans provided with the sales documents.12 Flagstone also requires homes to comply with the development scheme, the relevant lot plan and conditions in the contract.13

North Harbour publishes more of its setback rules. For lots under 450 m², the house generally has a 3 m front setback, while a double garage needs 4.5 m and a single garage 5.5 m. The secondary-street setback is 2 m. The guidelines also allow a boundary wall on one side of the lot, with a 1.5 m setback on the other side. On lots up to 27 m deep, the rear setback is 3 m. Deeper lots, and lots of 450 m² or more, need a 4.5 m rear setback.14

A two-storey part generally needs a 2 m side and rear setback. Boundary walls can be up to 15 m long and 3.5 m high. On frontages under 13 m, the 1.5 m side setback can reduce to 1 m in some cases.14 Estate guidelines can also measure setbacks differently. Aura and North Harbour measure from the wall or posts15, while some Flagstone guidelines measure from the outer edge of the building, including the roof.13

Boundary-wall rules also vary between estates. Harmony requires the wall to sit at least 200 mm inside the boundary16, SkyRidge allows 200 mm to 400 mm17, and Yarrabilba allows 50 mm to 200 mm.12

Each row reproduces the clause as the BuildStreet rulesets record it with the instrument, page and retrieval date; a guideline's stage edition governs its own stage only, and the per-lot plans named are not public. Harmony's guideline is Avid's July 2023 edition; whether it is still current is unconfirmed.
Siting clauses in seven south-east Queensland estate design guidelines, as verified in the BuildStreet rulesets, July 2026
Estate, guideline editionWhere the binding setbacks sitSetback measured toBoundary wall clause
North Harbour, Burpengary East, August 2023Appendix A table in the guideline: front 3.0 m, side 0 m and 1.5 m, rear 3.0 m or 4.5 m by lot size and depthWalls or postsMaximum 15 m long and 3.5 m high; 250 mm tolerance
Yarrabilba, Stockland, January 2025Per-lot setback plan, sales pack onlyNot stated in the guidelineSited 50 mm to 200 mm off the boundary
Springfield Rise, Lendlease, July 2018Per-lot setback plan, sales pack onlyNot stated in the guidelineNot stated in the guideline
Aura Acacia, Stockland, October 2023Per-lot plan of development; garages recessed 450 mm behind the front building lineThe wallNot stated in the guideline
Flagstone, Peet, stages 10 and 12, June 2026Plan of development and the Greater Flagstone development scheme; 450 mm eaves or the setback increased by 450 mmOutermost projectionBuilt-to-boundary excluded from the eave rule
Harmony, Avid, July 2023Release plan of development; height 8.5 mNot stated in the guidelineSlab and wall at least 200 mm inside the boundary
SkyRidge, Frasers, stages 10 and 11, May 2025Stage plan of development and Appendix A; garages 1 m behind the front wallNot stated in the guideline200 mm to 400 mm tolerance; maximum 12 m; no windows

Source · North Harbour Design Guidelines Stage 15-45 (31 August 2023); Yarrabilba Design Essentials (January 2025); Springfield Rise Home Design Guidelines (July 2018); Aura Design Essentials, Acacia (October 2023); Flagstone Design Guidelines Stage 10 and 12 (June 2026); Harmony Design Guidelines (July 2023); SkyRidge Design Guidelines Stages 10 and 11 (May 2025)

How those guidelines are approved and enforced, and what a plan of development is, are covered in the design guidelines article.

Section 08 · Finding the rule

Which setback rules apply to a block in Queensland?

The setback rules for a block can come from several different layers: the state rules, a priority development area or council planning scheme, and any estate-specific requirements.

The lot size determines which state rules apply, while the street type can affect the front setback for smaller lots. If the lot is inside a priority development area, its development scheme can set different requirements. Outside these areas, the council planning scheme can replace some of the state defaults with local rules.

In an estate, a lot-specific setback plan or development plan can add another layer of requirements. Some of these plans are issued with the sales documents and are not publicly available. BuildStreet checks these rule layers in order: the state rules first, then any priority development area or council requirements, followed by the estate rules where available. Where a lot-specific estate plan is not public, the setback result is treated as needing further siting information rather than being shown as a confirmed fit.

The Victorian and New South Wales stacks are covered in the ResCode article and the NSW front setback article.

How BuildStreet checks setback rules

BuildStreet applies these rules to each block using the lot's area and shape, the relevant QDC rules, any priority development area or council requirements, and available estate guidelines. It then shows the buildable area and which house designs fit. Where a lot-specific setback plan is not publicly available, the result is limited rather than treated as final.

Section 09

Frequently asked questions

What is the minimum front setback for a house in Queensland?

Under the Queensland Development Code, the default front setback is 6 m for lots of 450 m² or more. For lots under 450 m², it is generally 3 m on an access street or 4 m on a collector street. A different setback can apply where neighbouring houses are already closer to the road. Council or priority development area rules can also replace these defaults.

What is the side setback for a two-storey house in Queensland?

The general side and rear setback is 2 m for parts of a building between 4.5 m and 7.5 m high. Above 7.5 m, the setback increases. Smaller setbacks can apply on rectangular lots with a frontage of 15 m or less.

Can a house be built on the boundary in Queensland under the QDC?

A house wall generally cannot be built on the boundary under the standard QDC rules. A garage, shed or carport can sit closer to the boundary in some cases, subject to height, length and neighbouring-window requirements.

Does the QDC apply inside a priority development area?

A priority development area can have its own development scheme, which takes priority over the council's usual planning rules. Some schemes, including Yarrabilba, use the QDC setback rules for certain lots while also setting some of their own requirements.

Is the Queensland Housing Code in force?

The Queensland Housing Code started on 1 September 2026, but during the transition it applies in a council area only after that council adopts it through its planning scheme. Until then, the existing QDC or local council rules continue to apply. The transition ends on 1 September 2029.

Who approves a house that does not meet the QDC setbacks?

A design that does not meet the standard QDC setbacks may still be assessed through the building approval process. A private building certifier assesses the application, with the council involved where required.

References

  1. Queensland Development Code MP 1.1 — design and siting standard for single detached housing on lots under 450 m² · hpw.qld.gov.au ↑ b c d e f g h i j k l m
  2. Brisbane City Council: Building near the boundary · brisbane.qld.gov.au ↑ b c
  3. Building Act 1975 (Qld), section 65 (authorised reprint current as at 1 February 2026) · legislation.qld.gov.au ↑ b c
  4. Queensland Development Code MP 1.2, Design and siting standard for single detached housing on lots 450 m² and over (2010) · housing.qld.gov.au ↑ b c
  5. BuildStreet rule-stack method notes and Queensland rulesets (internal research notes, 7 and 8 July 2026) · BuildStreet ↑ b c d
  6. New Queensland Housing Code and Modern Homes Standards to make building homes easier (Queensland Government ministerial media statement 105747) · statements.qld.gov.au ↑ b c
  7. Logan Planning Scheme 2015 version 9.2, Part 9.3.2 Dual occupancy and Dwelling house code (Logan City Council, effective 1 July 2025) · s3-ap-southeast-2.amazonaws.com ↑ b c d e
  8. Economic Development Queensland: Priority Development Areas fact sheet (December 2025) · edq.qld.gov.au ↑ b c d
  9. Yarrabilba Priority Development Area Development Scheme, Amendment no. 2 (Economic Development Queensland, 28 February 2025) · edq.qld.gov.au ↑ b c
  10. Business Queensland, Queensland Development Code (register of current parts) · business.qld.gov.au ↑ b c d
  11. Queensland Housing Code (Queensland Department of Housing and Public Works) · housing.qld.gov.au ↑
  12. Yarrabilba Design Essentials (Stockland, January 2025) · stockland.com.au ↑ b
  13. Flagstone Design Guidelines, Stages 10 & 12 (Peet, June 2026) · peet.com.au ↑ b
  14. North Harbour Design Guidelines, Stages 15–45 (updated 31 August 2023) · northharbour.com.au ↑ b c
  15. Aura Design Essentials, Acacia precinct (October 2023) · stockland.com.au ↑
  16. Harmony Design Guidelines (Avid, July 2023) · web.archive.org ↑
  17. SkyRidge Design Guidelines: Botanica, Stages 10 & 11, Version 1 (May 2025) · mbh-static.fra1.cdn.digitaloceanspaces.com ↑
  18. Logan Planning Scheme 2015 version 9.2, Part 1 About the planning scheme (Logan City Council, effective 1 July 2025) · s3-ap-southeast-2.amazonaws.com
  19. Economic Development Queensland: Priority development areas · edq.qld.gov.au
  20. Flagstone Design Guidelines, Stage 1P & 1T (Peet, June 2026, version 2.0) · peet.com.au
  21. Springfield Rise Home Design Guidelines (13 July 2018) · communities.lendlease.com